Gas Safety and Compliance Policy
1. Purpose
The purpose of this policy is to establish a robust Gas Safety and Compliance Framework within {{org_field_name}} to protect the health, safety and wellbeing of people using our services, staff, visitors and any other persons who may be affected by our activities.
{{org_field_name}} will comply with all gas safety duties that apply to it in its capacity as a landlord, employer, service provider, managing agent or other dutyholder. Where a supported living property is owned or managed by a separate landlord or housing provider, statutory landlord gas safety responsibilities remain with the person or organisation upon whom those duties are imposed by law or contract. {{org_field_name}} will work with the landlord or housing provider to obtain appropriate assurance that relevant gas safety requirements have been met and will promptly report and escalate identified risks.
For Care Quality Commission regulated supported living services, a person’s own accommodation is not treated as premises provided as part of their care or treatment where the accommodation is separate from the provision of care. In those circumstances, Regulation 15 of the Health and Social Care Act 2008 (Regulated Activities) Regulations 2014 does not make {{org_field_name}} responsible for the safety or maintenance of the person’s home merely because regulated care is delivered there. However, {{org_field_name}} remains responsible for providing regulated care and treatment safely, assessing risks arising in connection with that care, taking reasonably practicable measures within its control and appropriately reporting or escalating environmental safety concerns to the landlord, housing provider or other responsible person.
This policy aims to:
- ensure compliance with applicable gas safety legislation, including the Gas Safety (Installation and Use) Regulations 1998, as amended, and the Health and Safety at Work etc. Act 1974;
- prevent and appropriately manage gas-related hazards, including carbon monoxide poisoning, gas leaks, fires and explosions;
- establish clear responsibilities between {{org_field_name}}, landlords, housing providers, managing agents, contractors and other relevant dutyholders;
- ensure applicable gas appliances, flues and installation pipework are appropriately checked and maintained;
- ensure staff understand how to recognise and respond to suspected gas and carbon monoxide emergencies; and
- maintain appropriate records and systems for monitoring compliance with duties for which {{org_field_name}} is responsible.
2. Scope
This policy applies to:
- premises owned, leased, rented, managed or controlled by {{org_field_name}} where {{org_field_name}} has legal or contractual responsibility for gas safety;
- supported living accommodation in which {{org_field_name}} provides care or support, to the extent that {{org_field_name}} has responsibilities for identifying, reporting, escalating or managing gas-related risks arising during the delivery of its services;
- gas appliances, flues, installation pipework and associated safety systems for which {{org_field_name}} has legal or contractual responsibility;
- offices and other workplaces controlled by {{org_field_name}} where gas appliances or gas installations are present; and
- staff, managers, contractors and other persons carrying out gas-safety-related functions on behalf of {{org_field_name}}.
In supported living arrangements where the accommodation is provided by a separate landlord or housing provider, the Registered Manager or other designated manager must establish and record who is responsible for statutory landlord gas safety duties. {{org_field_name}} must not assume that responsibility rests with the care provider merely because care or support is delivered at the property.
Where {{org_field_name}} is the landlord, or where responsibility has lawfully been assigned to {{org_field_name}} under the applicable arrangements, {{org_field_name}} will comply with the relevant landlord duties under the Gas Safety (Installation and Use) Regulations 1998, as amended.
Where another organisation is responsible for the accommodation, {{org_field_name}} will report identified gas safety concerns promptly to the landlord or housing provider and will take appropriate action within its own control to protect people receiving care and support while the concern is being addressed.
3. Legal and Regulatory Framework
This policy must be implemented in accordance with the legislation and regulatory requirements applicable to the particular premises and the legal capacity in which {{org_field_name}} operates.
3.1 Health and Social Care Act 2008 (Regulated Activities) Regulations 2014
Regulation 12 – Safe Care and Treatment
Where applicable to the regulated care or treatment being provided, {{org_field_name}} must:
- assess risks to the health and safety of people receiving care or treatment;
- do all that is reasonably practicable to mitigate identified risks;
- ensure that staff delivering regulated care have the qualifications, competence, skills and experience necessary to do so safely; and
- ensure premises and equipment used by the service provider in providing care or treatment are safe to use for their intended purpose.
In supported living, Regulation 12 does not make the care provider responsible for the safety of a person’s accommodation where that accommodation is not provided as part of the person’s care or treatment. The provider must nevertheless manage risks that affect the safe delivery of the regulated activity and appropriately report and escalate hazards identified in a person’s home.
Regulation 15 – Premises and Equipment
Where Regulation 15 applies, premises and equipment used by the service provider must be clean, secure, suitable for their intended purpose, properly used, properly maintained and appropriately located.
For supported living services, a person’s own accommodation is outside the scope of Regulation 15 where the accommodation is not provided as part of their care or treatment. Where a separate landlord or housing provider owns or manages the accommodation, responsibility for statutory housing and landlord gas safety requirements must therefore be determined separately.
3.2 Gas Safety (Installation and Use) Regulations 1998, as amended
Where {{org_field_name}} is a landlord or otherwise holds the relevant landlord duties, it must:
- maintain in a safe condition relevant gas appliances, flues and installation pipework for which it is responsible;
- ensure each relevant gas appliance and flue provided for tenants’ use receives a gas safety check at intervals of no more than 12 months, subject to the permitted timing arrangements under regulation 36A;
- ensure required gas safety checks and gas work are carried out by a suitably competent Gas Safe registered engineer who is appropriately registered for the category of work concerned;
- retain the required gas safety check record for at least two years, subject to the additional record-retention requirements where the regulation 36A early-check flexibility is used;
- give each existing tenant a copy of the gas safety check record within 28 days of the check being completed; and
- give a new tenant a copy of the current gas safety check record before they occupy the premises.
Where a tenant owns a gas appliance that has not been provided by the landlord, the landlord’s annual appliance safety-check duty does not extend to that tenant-owned appliance. However, any landlord responsibility for associated installation pipework must still be met.
3.3 Health and Safety at Work etc. Act 1974
{{org_field_name}}, as an employer, must ensure, so far as is reasonably practicable, the health, safety and welfare of its employees and must conduct its undertaking so that people who are not its employees are not exposed to risks to their health or safety.
Gas-related hazards affecting staff, people using services, contractors or visitors must therefore be identified and controlled where those risks arise from activities or premises for which {{org_field_name}} has responsibility.
3.4 Smoke and Carbon Monoxide Alarm (England) Regulations 2015, as amended by the Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022
Where the Regulations apply and {{org_field_name}} is the relevant landlord, {{org_field_name}} must:
- ensure that a carbon monoxide alarm is equipped in every room used wholly or partly as living accommodation which contains a fixed combustion appliance, other than a gas cooker;
- ensure prescribed smoke and carbon monoxide alarms are in proper working order on the first day of a new tenancy;
- following a report from a tenant or their nominated representative that a prescribed alarm may not be working, determine whether the alarm is in proper working order; and
- where the alarm is found not to be in proper working order, repair or replace it as soon as reasonably practicable.
These duties apply only where the tenancy and landlord fall within the scope of the Regulations. Responsibility must therefore be confirmed for each supported living property where the accommodation is provided by a separate landlord or housing provider.
4. Gas Safety Management at {{org_field_name}}
To effectively manage gas safety, {{org_field_name}} follows a structured approach that includes risk assessments, regular maintenance, staff training, and emergency planning.
4.1 Gas Risk Assessment and Compliance Checks
- A qualified Gas Safe engineer conducts a comprehensive risk assessment of all gas installations annually.
- The risk assessment covers:
- Condition of gas appliances, pipework, and flues.
- Ventilation and air circulation in rooms with gas appliances.
- Presence and functionality of carbon monoxide alarms.
- Emergency shut-off valves and accessibility.
- Any identified risks are documented in a Gas Safety Compliance Report, with corrective actions assigned immediately.
4.2 Annual Gas Safety Checks and Landlord Gas Safety Records
Where {{org_field_name}} is subject to the landlord duties under the Gas Safety (Installation and Use) Regulations 1998, as amended:
- each gas appliance and flue owned by the landlord and provided for the tenant’s use must receive a gas safety check at intervals of no more than 12 months by a suitably qualified Gas Safe registered engineer;
- installation pipework must be maintained in a safe condition but must not be incorrectly described as being subject to the same statutory annual appliance and flue safety-check requirement;
- where the flexibility permitted by regulation 36A is used, a gas safety check may be completed within the permitted period before its due date without changing the preserved deadline, provided all statutory conditions are satisfied;
- a Landlord Gas Safety Record must be produced containing the information required by the Regulations;
- the gas safety record must be retained for at least two years. Where the regulation 36A flexibility is relied upon, the relevant records must be retained for the period required to demonstrate compliance, including until two subsequent gas safety checks have been completed where applicable;
- each existing tenant must receive a copy of the gas safety check record within 28 days of the check being completed;
- each new tenant must receive a copy of the current gas safety check record before occupying the premises; and
- any defect or unsafe condition identified by the Gas Safe registered engineer must be managed in accordance with the engineer’s safety classification and instructions, and any appliance that has been made safe or isolated must not be returned to use until it is safe to do so.
Where another landlord or housing provider holds these statutory duties, {{org_field_name}} must report any identified concern to that organisation and, where necessary for the safe delivery of care, seek appropriate evidence that the concern has been addressed.
4.3 Installation, Servicing and Maintenance of Gas Appliances, Flues and Pipework
Where {{org_field_name}} is responsible for gas installations:
- gas appliances, flues and installation pipework for which {{org_field_name}} has responsibility must be maintained in a safe condition;
- installation, maintenance, repair and other gas work that falls within the Gas Safety (Installation and Use) Regulations 1998 must only be undertaken by a suitably competent Gas Safe registered engineer who is registered for the relevant category of gas work;
- gas appliances and flues must be maintained in accordance with applicable legal requirements and appropriate manufacturer’s instructions;
- installation pipework must be subject to appropriate inspection and maintenance so that it remains in a safe condition;
- defects identified during servicing, maintenance or safety checks must be acted upon in accordance with their level of risk and any instructions given by the Gas Safe registered engineer; and
- any appliance or installation that has been classified as unsafe and disconnected, isolated or otherwise made safe must not be returned to use until appropriate remedial work has been completed and it is safe to operate.
Where a separate landlord or housing provider is responsible for a supported living property, {{org_field_name}} must promptly communicate identified defects or safety concerns to that dutyholder and record any action taken to protect people receiving care while the matter is resolved.
4.4 Carbon Monoxide Monitoring and Prevention
Where {{org_field_name}} is the relevant landlord and the Smoke and Carbon Monoxide Alarm (England) Regulations 2015, as amended, apply:
- a carbon monoxide alarm must be equipped in every room used wholly or partly as living accommodation that contains a fixed combustion appliance, other than a gas cooker;
- each prescribed carbon monoxide alarm must be checked to ensure that it is in proper working order on the first day of a new tenancy;
- where a tenant or their nominated representative reports that an alarm may not be working, {{org_field_name}} must determine whether the alarm is in proper working order; and
- where the alarm is found not to be in proper working order, it must be repaired or replaced as soon as reasonably practicable.
Carbon monoxide alarms must be installed, tested, maintained and replaced in accordance with applicable legal requirements and the manufacturer’s instructions. Batteries must be replaced where required by the alarm manufacturer’s instructions or where necessary to restore the alarm to proper working order; there is no blanket requirement under these Regulations to replace every carbon monoxide alarm battery annually.
Where supported living accommodation is provided by a separate landlord or housing provider, responsibility for compliance with the landlord’s statutory carbon monoxide alarm duties must be confirmed with that landlord or housing provider. Staff must promptly report any missing, defective or activated carbon monoxide alarm to the responsible person and take immediate action where necessary to protect people from harm.
Staff and people receiving support, as appropriate to their needs and abilities, should be made aware of common symptoms associated with carbon monoxide exposure, including:
- headache;
- dizziness;
- nausea or vomiting;
- weakness;
- confusion;
- breathlessness; and
- collapse or loss of consciousness in serious cases.
Where a carbon monoxide alarm activates or carbon monoxide exposure is suspected, the emergency procedure in Section 6.2 of this policy must be followed.
5. Staff Training and Awareness
Fire Safety Lead: {{org_field_the_fire_safety_lead_name}}
Role: {{org_field_the_fire_safety_lead_role}}
To ensure that gas safety is effectively managed, all staff receive mandatory gas safety training covering:
- Recognising gas leaks, CO poisoning, and appliance malfunctions.
- How to shut off gas supply in an emergency.
- Steps to take if a CO alarm is triggered.
- Reporting procedures for faulty gas appliances.
Training is refreshed annually and recorded in staff training logs.
6. Emergency Procedures for Gas-Related Incidents
If a gas leak, fire, explosion, or carbon monoxide emergency occurs, the following emergency protocols must be followed:
6.1 Gas Leak Procedure
- Evacuate the area immediately – Do not attempt to fix the leak.
- Do not turn electrical switches on or off – This can ignite gas.
- Shut off the gas supply using the emergency shut-off valve.
- Open all windows and doors to ventilate the area.
- Call National Gas Emergency Service (0800 111 999).
- Inform the on-call manager and maintenance team.
- Only return to the premises after clearance from a Gas Safe engineer.
6.2 Carbon Monoxide Alarm Trigger Procedure
- Evacuate everyone from the affected area immediately.
- Do not re-enter the premises until advised by emergency services.
- Call emergency services and a Gas Safe engineer for immediate inspection.
- Provide medical attention if any service users or staff exhibit CO poisoning symptoms.
- Investigate the cause and take corrective actions (e.g., servicing or replacing faulty appliances).
7. Record Keeping and Compliance Monitoring
Where {{org_field_name}} holds statutory landlord gas safety responsibilities, it must maintain the records necessary to demonstrate compliance, including:
- current and previous Landlord Gas Safety Records;
- records demonstrating that existing tenants received the gas safety check record within 28 days of completion of the check;
- records demonstrating that new tenants received the current gas safety check record before occupying the premises;
- servicing, maintenance and repair records for gas appliances, flues and installation pipework for which {{org_field_name}} is responsible;
- records of identified defects, unsafe situations and remedial works;
- relevant carbon monoxide alarm checks, reports of defective alarms, investigations, repairs and replacements;
- records of gas-related incidents and emergency action;
- records of attempts to obtain access where a statutory gas safety check or necessary maintenance could not be completed because access was not available; and
- where the regulation 36A early-check flexibility is used, records sufficient to demonstrate that the statutory timing and retention requirements have been met.
Landlord Gas Safety Records must be retained for at least two years. Where {{org_field_name}} relies on the regulation 36A flexibility that allows a check to be completed within the permitted period before its due date while preserving the original deadline, the relevant record must be retained for the period required by the Regulations to demonstrate continued compliance, including until two subsequent gas safety checks have been completed where applicable.
Where the supported living accommodation is owned or managed by a separate landlord or housing provider, {{org_field_name}} is not required to duplicate statutory landlord records for which it has no legal responsibility. However, where gas safety affects the safe delivery of care or support, {{org_field_name}} must keep sufficient records to demonstrate that identified concerns have been reported, appropriately escalated and followed up.
Gas safety records held by {{org_field_name}} must be available for appropriate management oversight and regulatory or statutory inspection where required. Identified non-compliance must be escalated promptly and remedial action monitored to completion.
8. Continuous Improvement and Policy Review
- This policy is reviewed annually or sooner if legislative changes occur.
- Staff feedback, incident reports, and new regulations are used to improve safety procedures.
- Any updates to gas safety laws will be communicated promptly to all staff and contractors.
9. Policy Review
This policy is reviewed annually or whenever there is a change in gas safety regulations or operational requirements. Updates will be communicated to all staff, service users, and stakeholders.
Responsible Person: {{org_field_registered_manager_first_name}} {{org_field_registered_manager_last_name}}
Reviewed on: {{last_update_date}}
Next Review Date: {{next_review_date}}