{{org_field_logo}}
{{org_field_name}}
Registration Number: {{org_field_registration_no}}
Legionella Prevention and Water Safety Policy
1. Purpose
The purpose of this policy is to set out the arrangements implemented by {{org_field_name}} to identify, assess, prevent and control the risk of exposure to Legionella bacteria and to maintain safe hot and cold water systems throughout the care home.
This policy is implemented in accordance with the Health and Safety at Work etc. Act 1974, the Management of Health and Safety at Work Regulations 1999, the Control of Substances Hazardous to Health Regulations 2002 (COSHH), the Reporting of Injuries, Diseases and Dangerous Occurrences Regulations 2013 (RIDDOR), where applicable, the Regulation and Inspection of Social Care (Wales) Act 2016, and the Regulated Services (Service Providers and Responsible Individuals) (Wales) Regulations 2017, as amended, including Regulations 56 and 57 relating to hygiene, infection control and health and safety.
In controlling the risk from Legionella, {{org_field_name}} will have regard to the Health and Safety Executive Approved Code of Practice L8, Legionnaires’ disease: The control of Legionella bacteria in water systems, HSG274 Part 2, The control of Legionella bacteria in hot and cold water systems, HSG220, Health and safety in care homes, and other current applicable HSE, Welsh Government and Care Inspectorate Wales guidance.
{{org_field_name}} recognises that people living in care homes may be particularly susceptible to Legionnaires’ disease and to injury from excessively hot water. Water systems will therefore be designed, operated, monitored and maintained so that the risks from Legionella, scalding and other water-related hazards are identified and reduced so far as is reasonably practicable. Arrangements will take account of the needs, vulnerability and safety of individuals receiving care and support.
2. Scope
This policy applies to all staff, external contractors, and maintenance personnel who work with or manage the water systems, fixtures, and equipment at {{org_field_name}}. It applies to all areas of the premises where hot or cold water is stored, distributed, or used, including but not limited to taps, showers, sinks, storage tanks, toilets, spa baths, laundry rooms, kitchens, and garden irrigation systems. It also covers associated infrastructure such as pipework, thermostatic mixing valves (TMVs), and water heaters.
3. Related Policies
This policy should be read in conjunction with the following:
- CHW11 – Safe Care and Treatment Policy
- CHW16 – Health and Safety at Work Policy
- CHW17 – Infection Prevention and Control Policy
- CHW18 – Risk Management and Assessment Policy
- CHW19 – Emergency and Business Continuity Plan
- CHW24 – Management of Accidents, Incidents and Near Misses Policy
- CHW25 – Notification of Other Incidents Policy
4. Policy Statement and Implementation
4.1 Responsibilities and Competent Persons
The Service Provider, as the employer and/or person in control of the premises, retains legal responsibility for ensuring that risks arising from the water systems, including exposure to Legionella bacteria and scalding, are assessed and controlled so far as is reasonably practicable. The appointment of employees, contractors or external specialists to undertake particular water safety duties does not remove the Service Provider’s legal responsibility.
The Registered Manager is responsible for ensuring that the water safety arrangements required by this policy are implemented at the care home and that identified deficiencies and remedial actions are escalated to the Service Provider and addressed according to the level of risk.
A competent Responsible Person for Legionella and water safety will be formally appointed. The Responsible Person must have sufficient authority, competence, skills, knowledge of the water systems and experience to manage and implement the precautions required to control Legionella risk. Their appointment, responsibilities and authority will be documented.
The Responsible Person is responsible for:
- overseeing implementation of the Legionella risk assessment and written scheme of control;
- ensuring that required monitoring, inspection, flushing, cleaning, maintenance and remedial work is completed;
- ensuring that the water system schematic and associated water safety records remain current;
- reviewing monitoring results and acting promptly where control limits are not achieved;
- ensuring that staff undertaking water safety tasks have received appropriate instruction, information and training;
- coordinating the work of competent water hygiene contractors and other specialists;
- ensuring that identified defects or control failures are appropriately escalated and corrected; and
- maintaining appropriate records demonstrating implementation of the written scheme.
Where responsibility for water safety activities is shared between more than one person, individual duties, reporting arrangements and lines of accountability must be clearly defined in writing. Arrangements must also be in place to ensure that essential water safety controls continue during periods when the Responsible Person is absent.
Where specialist advice or work is required, {{org_field_name}} will appoint a competent Legionella risk assessor, water hygiene contractor or other suitably qualified person. The Responsible Person must satisfy themselves that contractors are competent to perform the work assigned to them and must monitor the satisfactory completion of that work.
All staff will be informed of how to report water safety concerns, including abnormal water temperature, discolouration, unusual odour, loss of water supply, defective outlets, defective thermostatic mixing valves or any other concern affecting the safety of the water system.
4.2 Legionella Risk Assessment
A suitable and sufficient Legionella risk assessment of the care home’s hot and cold water systems and any other water systems capable of creating a foreseeable risk of exposure to Legionella bacteria must be undertaken by a competent person.
The assessment must identify:
- the hot and cold water systems and any other relevant water systems present at the premises;
- persons who may be particularly susceptible to infection;
- potential sources of exposure to Legionella bacteria;
- factors which may encourage Legionella growth, including water temperatures between 20°C and 45°C, stagnation, low-use outlets, dead legs or dead ends, stored water, scale, sediment and biofilm;
- foreseeable exposure to water aerosols;
- existing control measures;
- monitoring, inspection and maintenance requirements;
- responsibilities for implementing and managing the controls; and
- any further measures required to prevent or adequately control the risk.
An up-to-date schematic diagram or other sufficiently detailed description of the hot and cold water systems must be maintained as part of the assessment and written control arrangements.
Where the assessment identifies a reasonably foreseeable risk from exposure to Legionella bacteria, a written scheme of control must be prepared and implemented. The written scheme must specify the water systems covered, the control measures to be used, the persons responsible for implementing those measures, the monitoring and inspection requirements, the required frequencies and control limits, and the actions to be taken where those limits are not achieved.
The Legionella risk assessment must be kept under review. There is no fixed statutory two-year reassessment interval. It must be reviewed regularly and whenever there is reason to believe that the existing assessment may no longer be valid, including where:
- there has been a change to the water system or its use;
- there has been a change to the building, its use or occupancy;
- there has been a change affecting individuals who may be particularly susceptible to Legionnaires’ disease;
- new information becomes available about risks or control measures;
- monitoring indicates that control measures are ineffective or required control limits are not being achieved;
- significant remedial works, alterations or commissioning have taken place;
- there has been a period of significant reduced occupancy, closure or interruption to normal water use;
- there has been a suspected or confirmed case of Legionnaires’ disease associated with the premises; or
- the Responsible Person otherwise considers that the assessment may no longer reflect the actual risks at the service.
Any actions identified by the assessment or subsequent review must be recorded, prioritised according to risk, allocated to a responsible person and completed within an appropriate timescale. Where an immediate risk to health is identified, immediate action must be taken to protect individuals, staff and others who may be exposed.
4.3 Water Temperature Monitoring, Legionella Control and Scalding Prevention
Where temperature is used as the primary means of controlling Legionella risk, the hot and cold water systems must be operated and monitored so that Legionella growth is adequately controlled while also protecting individuals from scalding.
Hot water must normally be stored in calorifiers at 60°C or above. Hot water distribution must be maintained so that water reaches at least 50°C within one minute at appropriate sentinel outlets before any thermostatic mixing valve or other point-of-use temperature-reducing device.
Cold water must be stored and distributed, so far as is reasonably practicable, below 20°C. Appropriate cold water sentinel outlets must achieve a temperature below 20°C within two minutes of running.
Sentinel outlets must be identified to represent the hot and cold water distribution system, including appropriate outlets nearest to and furthest from the relevant calorifier or storage vessel. Sentinel temperatures will be checked at least monthly. Where {{org_field_name}} operates a more frequent monitoring schedule, such as weekly monitoring, that higher frequency will be maintained unless the Legionella risk assessment and written scheme are formally reviewed and amended by a competent person.
Hot water storage temperatures will be checked and recorded at least monthly. Where a calorifier has flow and return circulation, the flow and return temperatures will be monitored in accordance with the written scheme to demonstrate that the required distribution temperatures are being maintained.
Cold water storage tank temperatures will be checked at least every six months, including during conditions likely to represent the highest incoming or stored cold water temperatures. Any additional monitoring specified by the Legionella risk assessment or written scheme must also be completed.
Where individuals are vulnerable to scalding, individual and environmental scalding risks must be assessed. Where vulnerable individuals have access to baths or showers and there is a significant risk of scalding during whole-body immersion, suitable thermostatic mixing valves or other suitable engineering controls must be provided so that water is not discharged at temperatures above 44°C.
Thermostatic mixing valves must be positioned as close as reasonably practicable to the outlet in order to minimise the volume of blended water in which Legionella could grow. They must be inspected, maintained and tested at intervals determined by the risk assessment, manufacturers’ instructions and relevant guidance to ensure that they continue to control outlet temperature effectively.
Where an individual is identified as vulnerable to scalding from a wash-hand basin or another hot water outlet, suitable controls must also be implemented based on the assessed risk.
Staff assisting an individual with bathing or showering must follow the individual’s assessed care arrangements and safe bathing procedures, including checking the water temperature by an appropriate method before the individual enters the bath or shower where this is required by their risk assessment or personal plan.
All temperature monitoring results must be recorded. Any temperature outside the specified control limits, failure of a thermostatic mixing valve, inability to achieve the required distribution temperature, or other indication that the control regime may have failed must be reported promptly to the Responsible Person. The cause must be investigated and appropriate corrective action taken and recorded.
Where temperature control limits cannot be consistently achieved, the effectiveness of the Legionella control regime must be reviewed by a competent person and alternative or additional control measures implemented where necessary.
4.4 Flushing of Infrequently Used Outlets
All outlets that are infrequently used, including those in spare bedrooms, temporarily unoccupied rooms, disused toilets, bathrooms or other areas, must be identified as part of the Legionella risk assessment and written scheme of control.
Infrequently used outlets must be flushed at least weekly, or at another frequency determined by the Legionella risk assessment and written scheme of control, to reduce the risk of stagnation and deterioration in water quality.
Flushing must be undertaken in a manner that minimises the production of aerosols and avoids unnecessary exposure of individuals, staff and others to potentially contaminated water.
The flushing procedure must ensure that fresh water is drawn through the relevant branch of the system and that hot and cold water temperatures are restored towards their normal operating conditions.
Any outlet which is unused for more than one week must be considered for inclusion within the low-use outlet flushing schedule unless the risk assessment demonstrates that an alternative control arrangement is appropriate.
A flushing record must be maintained which identifies:
- the outlet or location;
- the date of flushing;
- the person completing the task;
- any abnormal observation or concern identified; and
- any corrective action required or undertaken.
Where outlets are no longer required, consideration must be given to removing associated redundant pipework or otherwise eliminating the risk of stagnation.
4.5 Cleaning and Descaling of Showerheads and Taps
Showerheads, shower hoses and removable tap components must be maintained in a clean condition and free from excessive scale, sediment and biofilm.
Showerheads and hoses must be dismantled where practicable, cleaned, descaled and disinfected at least quarterly, or more frequently where required by the Legionella risk assessment, water quality, local conditions or manufacturers’ instructions.
The cleaning and disinfection process must follow a documented procedure and use suitable cleaning and disinfecting products in accordance with the manufacturers’ instructions and relevant health and safety requirements.
Staff undertaking this task must use appropriate personal protective equipment and follow safe working procedures to minimise exposure to cleaning chemicals, aerosols and contamination.
Where showerheads, hoses, taps or associated components are damaged, heavily contaminated or cannot be adequately cleaned and descaled, they must be replaced.
Records must be maintained showing:
- the outlet or equipment cleaned;
- the date of cleaning and descaling;
- the person who completed the task;
- any defect or concern identified; and
- any replacement or remedial action undertaken.
4.6 Cold Water Storage and Hot Water System Maintenance
Cold water storage tanks, calorifiers, water heaters and associated equipment must be included within a planned inspection and maintenance programme based on the Legionella risk assessment, written scheme of control, system design and manufacturers’ instructions.
Cold water storage tanks must be inspected periodically to assess their internal condition and to ensure that they are:
- clean and free from significant sediment, debris and contamination;
- adequately covered and protected from ingress of contaminants;
- appropriately insulated;
- structurally sound;
- fitted and configured to promote satisfactory water turnover; and
- not subject to conditions that could cause stored water temperatures to rise unnecessarily.
Where inspection identifies significant sediment, contamination, deterioration or another condition that may increase Legionella risk, appropriate cleaning, disinfection, repair or other remedial work must be arranged.
Calorifiers and other hot water storage systems must be maintained so that required storage and distribution temperatures can be achieved and sustained.
Where appropriate, calorifiers must be inspected, drained, cleaned or otherwise maintained in accordance with the written scheme of control and competent technical advice.
Expansion vessels and other components capable of creating stagnation must be included within the Legionella risk assessment and monitored or flushed where necessary.
Water sampling for Legionella or other microbiological parameters will not be used as a substitute for adequate system control. Sampling will be undertaken where indicated by the Legionella risk assessment, where control measures are not being consistently achieved, following certain incidents or remedial works, or where advised by a competent water hygiene specialist, public health authority or other relevant professional.
Any sampling must be undertaken by a competent person using an appropriate sampling protocol and an appropriately accredited laboratory.
All inspection, maintenance, cleaning, disinfection and sampling records must be retained within the Water Safety and Legionella Logbook.
4.7 Control of Contractors and Water System Works
All external contractors engaged to assess, inspect, maintain, alter, clean, disinfect, sample or otherwise work on the water systems must be appropriately competent for the work they are required to perform.
Before appointing a contractor, {{org_field_name}} must take reasonable steps to establish their competence, including consideration of relevant qualifications, training, experience, professional accreditation or membership, technical capability and previous performance, where appropriate.
Contractors must be provided with relevant information about:
- the care home environment;
- known Legionella and water safety risks;
- vulnerable individuals who may be affected by the work;
- relevant parts of the Legionella risk assessment and written scheme;
- site-specific health and safety requirements; and
- emergency and reporting arrangements.
Where appropriate, contractors must provide suitable risk assessments, method statements and evidence of competence before work begins.
Any planned alteration, installation, repair or other work affecting the water system must be assessed for its potential effect on Legionella risk, water temperatures, stagnation, dead legs, water turnover and scalding controls.
The Responsible Person must ensure that the Legionella risk assessment, water system schematic and written scheme of control are reviewed and updated where water system alterations materially affect the existing arrangements.
Following significant water system work, appropriate flushing, commissioning, cleaning, disinfection, temperature verification and, where indicated by the risk assessment or competent advice, water sampling must be completed before the affected system is returned to normal use.
The Responsible Person must ensure that contractor reports, certificates and recommendations are obtained and reviewed and that any required remedial actions are completed.
The use of external contractors does not transfer the Service Provider’s legal responsibility for ensuring that risks from Legionella and water systems are adequately controlled.
4.8 Suspected Legionella Case, Outbreak Response and Incident Reporting
Any suspected or confirmed case of Legionnaires’ disease or other significant water safety incident potentially associated with the premises must be treated as a serious incident and escalated immediately to the Registered Manager and Responsible Person.
The immediate priority will be to protect individuals, staff, visitors and contractors from further exposure. The Registered Manager and Responsible Person must obtain urgent advice from the appropriate health protection or public health authority and, where necessary, a competent water hygiene specialist.
Any restriction, isolation, shutdown, sampling, disinfection or other alteration of the water system must be undertaken on the basis of competent advice and the assessed circumstances. Actions must not unnecessarily create additional water stagnation or other risks.
Where an outbreak of infectious disease occurs, the Service Provider must notify Care Inspectorate Wales in accordance with Regulation 60 and Schedule 3 of the Regulated Services (Service Providers and Responsible Individuals) (Wales) Regulations 2017, as amended. The notification must be made without delay, in writing and using the manner or form required by Care Inspectorate Wales. The Service Provider must not delay notification while awaiting completion of an internal investigation.
Where a water safety incident prevents, or could prevent, {{org_field_name}} from continuing to provide the service safely, Care Inspectorate Wales must also be notified where the circumstances fall within the applicable Schedule 3 notification requirements.
Where the service provides accommodation to children, any additional statutory notifications to the relevant placing authority, local authority, police, health board or other body must also be made where the circumstances fall within the relevant legal notification requirements.
Where a worker has been diagnosed with a disease attributable to occupational exposure to Legionella bacteria or another biological agent and the circumstances meet the requirements of the Reporting of Injuries, Diseases and Dangerous Occurrences Regulations 2013, the responsible person under RIDDOR must ensure that the required report is made to the relevant enforcing authority.
The Registered Manager and Responsible Person must cooperate with the relevant health protection or public health authority, Care Inspectorate Wales, the relevant health and safety enforcing authority, environmental health officers and any other statutory body involved in investigating or managing the incident.
The response may include, according to professional advice and the circumstances:
- protecting individuals from exposure to potentially affected outlets or systems;
- identifying individuals who may have been exposed or who are particularly susceptible;
- arranging appropriate microbiological water sampling by competent persons where required;
- reviewing temperature and monitoring records;
- reviewing the Legionella risk assessment and written scheme of control;
- investigating possible failures of control;
- undertaking remedial engineering works, cleaning or disinfection;
- reviewing relevant staff practices and training;
- maintaining detailed records of decisions, actions and professional advice received; and
- confirming that the system is safe before normal use is resumed where use has been restricted.
All suspected or confirmed Legionella incidents and outbreaks must be recorded and investigated. Following the incident, the Legionella risk assessment, written scheme of control and relevant procedures must be reviewed and revised where necessary.
Identified learning and remedial action must be incorporated into the service’s health and safety and quality assurance arrangements.
The incident must also be managed and reported in accordance with CHW24 – Management of Accidents, Incidents and Near Misses Policy and CHW25 – Notification of Other Incidents Policy.
4.9 Staff Training, Instruction and Awareness
All staff must receive appropriate information, instruction and training relevant to their role concerning water safety, Legionella prevention and the reporting of water-related concerns.
As part of induction, staff must be made aware of:
- the importance of maintaining safe water systems;
- the increased vulnerability of some individuals to Legionnaires’ disease and scalding;
- how to report water temperature concerns;
- how to report discoloured, cloudy or unusually smelling water;
- how to report reduced water pressure or interrupted water supply;
- how to report defective taps, showers, thermostatic mixing valves or other water equipment;
- the importance of avoiding unauthorised changes to water systems or outlets; and
- the person to whom water safety concerns must be reported.
Staff who undertake Legionella control tasks, including temperature monitoring, outlet flushing, cleaning and descaling, thermostatic mixing valve checks or other water safety monitoring, must receive training and instruction appropriate to the tasks they perform.
Their competence must be assessed before they undertake those tasks without supervision.
Training must include, where relevant:
- the nature and health effects of Legionella bacteria;
- factors that encourage Legionella growth;
- the purpose of the written scheme of control;
- correct monitoring and flushing techniques;
- methods of reducing exposure to aerosols;
- safe temperature measurement;
- recognising abnormal results;
- recording requirements;
- escalation procedures; and
- the action to take where required control limits are not achieved.
The Responsible Person must receive training appropriate to the responsibilities of the role and must maintain sufficient knowledge and competence to manage the water safety arrangements effectively.
Training must be refreshed where necessary, including following significant changes to the water system, written scheme, legislation or guidance, where monitoring identifies deficiencies in practice, or where an incident demonstrates that further training is required.
Training and competency records must be maintained.
4.10 Documentation, Record Keeping, Monitoring and Audit
A Water Safety and Legionella Logbook must be maintained in a form that enables {{org_field_name}} to demonstrate implementation and oversight of its water safety arrangements.
The records must include, as applicable:
- the name, position and responsibilities of the person or persons responsible for undertaking the Legionella risk assessment and for managing and implementing the written scheme of control;
- the current Legionella risk assessment and previous superseded assessments;
- the written scheme of control and evidence of its implementation;
- an up-to-date schematic diagram or other appropriate description of the water systems;
- details of the operational status of relevant water systems, including systems or parts of systems that are temporarily or permanently out of use;
- hot and cold water temperature monitoring records;
- calorifier and cold water storage monitoring records;
- flushing records for infrequently used outlets;
- showerhead, hose and outlet cleaning and descaling records;
- inspection, servicing and maintenance records for water systems and associated equipment;
- thermostatic mixing valve inspection, testing and maintenance records;
- cold water storage tank and calorifier inspection records;
- water sampling and microbiological analysis results where sampling has been undertaken;
- cleaning and disinfection records and certificates;
- records of identified defects, failures of control limits and corrective or remedial actions;
- records of alterations, commissioning or significant works affecting the water system;
- contractor reports, competence information and relevant certification;
- staff training and competence records;
- details of suspected or confirmed water-related infection incidents and actions taken; and
- records of reviews, audits and resulting improvement actions.
Records relating to the Legionella risk assessment, written scheme and other records required under the control arrangements must be retained for the period for which they remain current and for at least two years afterwards.
Records of monitoring, inspections, tests and checks carried out under the Legionella control regime, including the dates on which they were undertaken, must be retained for at least five years.
Records must clearly identify who performed the relevant task and when it was completed and must be signed, verified, authenticated electronically or otherwise attributable to the person who carried out or verified the work.
The Responsible Person must routinely review monitoring records to identify non-compliance, repeated abnormal results, trends or evidence that control measures may not be effective.
Required corrective action must be recorded, assigned and followed through to completion.
The Registered Manager must ensure that water safety forms part of the service’s health and safety governance and audit arrangements. Significant risks, repeated control failures and overdue high-risk remedial actions must be escalated to the Service Provider.
The Responsible Individual’s quality monitoring and review arrangements must have access to relevant water safety information where this is necessary to provide assurance that health and safety risks are being effectively controlled.
Water safety documentation must be made available to Care Inspectorate Wales, the relevant health and safety enforcing authority or another authorised statutory body when lawfully required.
4.11 Water System Alterations, Reduced Use, Shutdown and Recommissioning
Any planned alteration, extension, shutdown, prolonged reduction in occupancy or other significant change affecting the hot or cold water system must be considered for its potential impact on Legionella risk before the change is implemented.
The Responsible Person must ensure that the Legionella risk assessment and written scheme of control are reviewed where the change may affect the validity of the existing assessment or the effectiveness of existing controls.
Water must not be allowed to remain unnecessarily stagnant within the system.
Redundant pipework and dead legs identified as presenting a risk must be removed or otherwise appropriately controlled so far as is reasonably practicable.
Where rooms, outlets or parts of the building are temporarily unused, they must be included within the low-use outlet monitoring and flushing arrangements specified by the written scheme.
Where a water system or part of a system has been shut down, significantly altered, newly commissioned or left unused for a prolonged period, the Responsible Person must obtain competent advice where necessary and ensure that appropriate flushing, cleaning, disinfection, temperature verification, sampling or other control measures required by the risk assessment are completed before the system is returned to normal use.
The actions undertaken before recommissioning and the confirmation that the system is suitable for use must be documented.
5. Policy Review
This policy is reviewed annually or earlier if there are changes in legislation, CIW guidance, or following a significant water safety incident. The Registered Manager and Responsible Person for Water Safety are jointly responsible for ensuring that the policy remains accurate and effective.
Responsible Person: {{org_field_registered_manager_first_name}} {{org_field_registered_manager_last_name}}
Reviewed on: {{last_update_date}}
Next Review Date: {{next_review_date}}
Copyright © {{current_year}} – {{org_field_name}}. All rights reserved.